With over 20 years of industry experience, Jumbo Stud Partitions has established itself as the UK’s number one provider of jumbo stud partition solutions, delivering technically advanced, fire-rated and acoustic partition systems for some of the most demanding environments in the country.
We specialise exclusively in large-scale, high-performance partitioning, offering a level of expertise, engineering knowledge and delivery capability that sets us apart from conventional partition contractors.
Jumbo Stud Partition Systems can be configured to meet a range of fire resistance requirements. Jumbo stud fire-rated systems are available with 30, 60 and 120 minute fire resistance, while composite panel fire-rated systems can achieve higher ratings of up to 240 minutes, subject to system specification and build-up.
The required fire rating is normally determined by the building’s fire strategy, compartmentation layout, use of the space and any insurer requirements. Fire consultants typically define the required fire resistance period, and we can advise on the most suitable partition system to meet that requirement.
Yes. Our fire-rated partition systems are designed specifically for industrial and commercial environments and are commonly used to form internal fire separation and fire compartmentation walls in warehouses, distribution centres, factories and large commercial buildings.
Yes. Fire performance depends on the complete system build-up and correct installation. Junctions, interfaces, penetrations, openings and fire stopping must all be detailed and installed correctly to achieve the intended fire resistance.
Service penetrations, doors and openings must be detailed to maintain the integrity of the fire-rated construction. Fire stopping and interface detailing should be carried out in accordance with the project fire strategy and relevant specifications. We can provide guidance on compatible detailing and typical solutions.
Yes. We can provide fire performance information and technical guidance to support specification, tender queries and approvals. Where applicable, relevant system documentation and project-specific technical clarification can also be supplied.
To recommend the correct system, we typically require the fire resistance period, wall height, layout drawings, details of doors and openings, and information on any service penetrations or interface conditions. Where available, the project fire strategy is also helpful.
Yes. For projects with higher fire resistance requirements, composite panel partition systems can be specified to provide increased fire performance, including options up to 240 minutes, subject to system selection and specification.
Our acoustic partition systems can be configured to achieve a range of sound reduction performance levels, with options up to 72dB, depending on system selection, build-up and project requirements.
A dB rating indicates the partition’s ability to reduce airborne sound transmission. Higher dB values generally indicate better sound insulation, although actual performance depends on the complete construction, interfaces and installation quality.
Yes. Our acoustic jumbo stud partition systems are designed for robust industrial and commercial use and are commonly specified where noise separation is required between processes, departments, offices or noise-sensitive areas.
Acoustic performance is strongly influenced by installation quality. Junction sealing, perimeter detailing, penetrations, doors and service routes all affect performance. Even small gaps or poorly sealed interfaces can significantly reduce sound insulation.
Doors and openings can be performance-limiting elements in an acoustic wall. They should be specified to an appropriate acoustic rating and detailed correctly with suitable seals and frames. We can advise on suitable approaches based on the required overall performance.
Yes. If you provide your target dB performance, wall height and layout, we can recommend an appropriate system configuration and highlight key detailing considerations to help achieve the intended acoustic outcome.
Yes. We can provide acoustic performance information and technical guidance to support specification, tender and consultant queries where required.
High-performance acoustic partitions are commonly used in film and broadcast studios, cinemas, performance spaces, training rooms, offices within industrial buildings and other environments where controlling airborne noise is critical.
(For Building Control, Insurers & Fire Strategy Documentation)
Jumbo Stud Partition Systems can be configured to provide fire resistance periods in line with project fire strategies. Jumbo stud fire-rated systems are available with fire resistance periods of 30, 60 and 120 minutes, while composite panel fire-rated systems can be specified for higher fire resistance requirements of up to 240 minutes, subject to system selection and configuration.
Fire resistance performance is dependent on the complete system build-up and correct installation in accordance with the project specification.
The required fire resistance period for internal partitions is typically determined by the project fire strategy, building use, compartmentation requirements and any insurer or authority requirements. System selection should be coordinated with the appointed fire consultant to ensure compatibility with the overall fire safety strategy.
Jumbo Stud Partitions can provide technical guidance to support the selection of an appropriate system based on these requirements.
Fire-rated partition systems supplied by Jumbo Stud Partitions are intended for use in industrial and commercial environments, including warehouses, distribution centres, factories and large-scale commercial buildings, where internal fire separation and compartmentation is required.
The achieved fire resistance of the partition system is dependent on correct installation and detailing. Particular attention must be given to:
Junctions with floors, soffits and structural elements
Interfaces with adjoining constructions
Openings, doors and service penetrations
Fire stopping and sealing
All detailing and fire stopping should be carried out in accordance with the project specification, relevant standards and the fire strategy.
Where openings, doors or service penetrations are required within a fire-rated partition, these elements must be detailed and protected to maintain the integrity of the fire-resisting construction. The responsibility for correct detailing and installation lies with the contractor in accordance with the approved design and fire strategy.
Technical information and system guidance can be provided to support specification, tender queries and compliance documentation. Where applicable, relevant performance documentation and project-specific clarification may also be supplied.
To support system selection and compliance review, the following information is typically required:
Required fire resistance period
Partition height and layout
Details of openings and penetrations
Interface conditions
Project fire strategy (where available)
(For Building Control, Insurers & BCO-Style Documentation)
Jumbo Stud acoustic partition systems can be configured to achieve a range of airborne sound insulation performance levels. Depending on system selection and construction, acoustic performance of up to 72dB can be achieved, subject to specification and installation.
Acoustic performance is dependent on the complete system build-up and correct site installation.
The required acoustic performance of internal partitions is typically defined by the project brief, building use and any relevant acoustic assessments. System selection should be coordinated with the appointed acoustic consultant to ensure the proposed partition construction is suitable for the intended use.
Achieved acoustic performance is highly sensitive to installation quality. Particular attention must be given to:
Perimeter sealing and junction detailing
Continuity of construction
Treatment of service penetrations
Acoustic detailing of doors and openings
Poor detailing or gaps within the construction can significantly reduce performance.
Doors and openings within acoustic partitions can represent a performance-limiting element. Where required, doors should be specified to an appropriate acoustic rating and installed with suitable frames and seals in accordance with the project specification.
Acoustic partition systems are suitable for use in industrial and commercial buildings where control of airborne sound transmission is required, including separation between noisy processes, offices, studios, cinemas and other noise-sensitive spaces.
Acoustic performance information and technical guidance can be provided to support specification, tender documentation and consultant review where required.
To support acoustic system selection, the following information is typically required:
Target acoustic performance
Partition height and layout
Details of doors, openings and penetrations
Interface and junction conditions
If you’re planning a project that demands jumbo stud partition solutions, fire-rated acoustic performance, or extreme heights, we’re ready to help.
📞 Call: 01425 472748
🌐 www.jumbostudpartitions.co.uk
📧 Contact us to discuss your requirements
At Jumbo Stud Partition Systems we continually strive to improve our fire rated acoustic partition systems, resourcing materials from recycled products and recycling all residual waste whenever possible, in turn, helping the environment, and to pass on any cost savings to our clients. We are always striving to develop our systems on a continual basis.
JPS30FS Jumbo Stud Partition Systems
JPS60FS Jumbo Stud Partition Systems
JPS120FS Jumbo Stud Partition Systems
Jumbo Stud Partition Systems has been working closely with a good number of architects over a number of years to help specify and ultimately install Jumbo Stud Partition Systems. All of our partitioning systems come with fire certification and for Peace of Mind, a system warranty.
| Cookie | Duration | Description |
|---|---|---|
| cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
| cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
| cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
| cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
| cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
| viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |